APC InRow 1 Rack SX 600mm/Air Rear Cont

Forsiden / APC InRow 1 Rack SX 600mm/Air Rear Cont
For at se vore priser skal du være oprettet som kunde: Er du allerede oprettet som kunde skal du logge ind.
APC InRow 1 Rack SX 600mm/Air Rear Cont (RACSC101E)
APC InRow 1 Rack SX 600mm/Air Rear Cont (RACSC101E)
APC InRow 1 Rack SX 600mm/Air Rear Cont (RACSC101E)
APC InRow 1 Rack SX 600mm/Air Rear Cont (RACSC101E)

APC InRow 1 Rack SX 600mm/Air Rear Cont

Varenr.:
RACSC101E
  • Effekt 0VA
  • Produkt Tilbehør
Forventes på lager 03-11-2020
Beskrivelse

InRow SC System 1 InRow SC 50Hz 1PH, 1 NetShelter SX Rack 600mm, and Rear Containment


Close-coupled, air, water, and glycol cooling for closets, server rooms, and data centers

General

  • Compressor Type Rotary
  • Intake Air Rear Return
  • Refrigerant Charge 1.36 KG
  • Air Flow 566.34 lps
  • Amp Draw In-Rush 65A
  • Condensate Pump Capacity 0.002 lps

Input

  • Number of Power Cords 1
  • Nominal Input Voltage 200,208,220,230
  • Input Power 2390 Watts
  • Input Frequency 50 Hz
  • Rack Height 42U
  • Input Connections IEC 309 16A 2P+E

Communications & Management

  • Control panel Multi-function LCD status and control console

Physical

  • Maximum Height 1991.00 mm
  • Maximum Width 900.00 mm
  • Maximum Depth 1273.00 mm
  • Net Weight 331.68 KG
  • Color Black

Environmental

  • Storage Temperature 0 - 40 °C
  • Storage Relative Humidity 0 - 95%
  • Storage Elevation 0-4500 meters
  • Audible noise at 1 meter from surface of unit 80.00 dBA

Conformance

  • Standard Warranty 1 year (parts only)

Features

Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.

Features & Benefits

Availability

Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.

Reduces the risk of hot spots at the rack level

Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.

Total Cost of Ownership

Variable speed fans reduce energy consumption during off-peak cooling periods.

Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.

Agility

Modular design provides scalable solutions to add cooling as demand increases.

Allows for higher cooling to be achieved by integrating the Hot Aisle Containment System with row-based architecture.

Serviceability

Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.

Manageability

Utilizes intelligent, active response control, and real-time monitoring. The system is controlled by a microprocessor providing high level control functionality and human interface via a four line, eighty character, alphanumeric display

Send alarms and data points allowing you to manage critical building infrastructure from a single system.

Real-time display of current and available cooling.

Selvom vi gør vort bedste for at give fyldestgørende information, så er billederne kun vejledende, og selve varen er ikke nødvendigvis 100% identisk med det viste billede. Produkter kan være vist med ekstraudstyr der ikke er inkluderet eller i andre form- og farvevarianter. Hvis der er forskel mellem produktoverskrift, beskrivelse og billede, så er det produktoverskriften som gælder. Hvis du er i tvivl, så kontakt os gerne. Vi tager forbehold for trykfejl, ændring af priser og specifikationer uden varsel.